Results and conclusions of fitting restriction washers to correct water distribution over cylinder blocks.
| Identifier | ExFiles\Box 179b\3\ img243 | |
| Date | 16th February 1933 | |
| -2- Hs {Lord Ernest Hives - Chair} /Yng.2/WJ.16.2.33. Cont'd. {John DeLooze - Company Secretary} RESULTS. The restriction washers fitted to correct the water distribution over the cylinder blocks were as follows :- Nos. 1 to 4 outlet ports - No restriction. Nos. 6,7 & 8 outlet ports - One 1/4" dia. hole. Nos. 5 & 9 outlet ports - One 3/16" dia. hole. NOTE - The ports are numbered from 1 to 9 from the front. (The existing horn pipe washers were retained, i.e. 13/16" dia. hole). Curve 383F. shews the condition of the water flow as for the Type Test (Case 1) and in addition for the corrected state (Case 2). Curve 384F. shews the condition of the water flow when running evaporatively cooled at the endurance power and R.P.M. for the Goshawk(Aero Engine)(Codename for 20HP Car / Aero Engine after Kestrel(Aero Engine)) ll rating. Curve 385F. gives the water flows under the various conditions required to cover the Type Test Schedule. The table attached shews pressures taken at various points when running with the block in the original and corrected forms. Water reversal tests were carried out under the standard conditions (See report ref: Hs {Lord Ernest Hives - Chair} /Yng.2/WJ.19.11.32) using a header tank to INS.157. The condition of the blocks in the corrected state was very slightly worse for reversals than previously. No results are given for the water displacement test as a peculiar characteristic was exhibited and a re-check is considered necessary. This re-check will be carried out using a different header tank. CONCLUSIONS. Although the temperatures have been levelled up by means of the restriction washers, and the water flows in the corrected form are normal, DES.1613 cylinder blocks in our opinion still do not represent any improvement over the present standard. A concrete fact supporting this is revealed on examination of the results given on the table of pressures No.934. It will be seen that the water outlet pressures calculated from the temperatures are, for the rear of the water outlet pipe lower than those actuall | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).