Graph showing the effect of temperature and restriction on the Phantom II cooling system's water flow and pump suction side depression.

Identifier  WestWitteringFiles\U\January1930-April1930\  Scan048
Date  13th January 1930
  
PHANTOM II COOLING SYSTEM
EFFECT OF TEMPERATURE AND RESTRICTION ON WATER FLOW AND SUCTION SIDE DEPRESSION.
RESTRICTION USED IS A PLATE DRILLED WITH ONE HOLE .6" DIAM. PLACED IN THE DELIVERY PIPE JOINT TO THE PUMP.
LEGEND:
STANDARD SYSTEM SUCTION SIDE TEMP 60°C
STANDARD SYSTEM SUCTION SIDE TEMP 85°C
RESTRICTED SYSTEM SUCTION SIDE TEMP 60°C
RESTRICTED SYSTEM SUCTION SIDE TEMP 85°C
AXES:
WATER FLOW THROUGH TOP PIPE (GALLS/MIN:)
DEPRESSION ON SUCTION SIDE OF PUMP (INS: MERCURY)
ENGINE R.P.M.
LABELS:
WATER FLOW
DEPRESSION ON SUCTION SIDE OF PUMP
OTHER:
1.
STAMP:
ROLLS-ROYCE LTD.
PRINT ROOM
JAN 13 1930
DERBY
  
  