Graph showing the effect of temperature and restriction on the Phantom II cooling system's water flow and pump suction side depression.
| Identifier | WestWitteringFiles\U\January1930-April1930\ Scan048 | |
| Date | 13th January 1930 | |
| PHANTOM II COOLING SYSTEM EFFECT OF TEMPERATURE AND RESTRICTION ON WATER FLOW AND SUCTION SIDE DEPRESSION. RESTRICTION USED IS A PLATE DRILLED WITH ONE HOLE .6" DIAM. PLACED IN THE DELIVERY PIPE JOINT TO THE PUMP. LEGEND: STANDARD SYSTEM SUCTION SIDE TEMP 60°C STANDARD SYSTEM SUCTION SIDE TEMP 85°C RESTRICTED SYSTEM SUCTION SIDE TEMP 60°C RESTRICTED SYSTEM SUCTION SIDE TEMP 85°C AXES: WATER FLOW THROUGH TOP PIPE (GALLS/MIN:) DEPRESSION ON SUCTION SIDE OF PUMP (INS: MERCURY) ENGINE R.P.M. LABELS: WATER FLOW DEPRESSION ON SUCTION SIDE OF PUMP OTHER: 1. STAMP: ROLLS-ROYCE LTD. PRINT ROOM JAN 13 1930 DERBY | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).