Observations on equivalent wire gauges for fuses on main and accessory distribution boards.
Identifier | WestWitteringFiles\T\November1928\ Scan033 | |
Date | 16th November 1928 | |
To E.{Mr Elliott - Chief Engineer} from EFC. V.{VIENNA} BY.{R.W. Bailey - Chief Engineer} BY/HD.{Mr Hayward/Mr Huddy} DISTRIBUTION BOARDS Further to our EFC2/T2.11.28, with reference to double and single wire fuses for the main and accessory distribution boards respectively, with a view to arriving at a gauge of double wire which is equivalent to our single 30 S.W.G., we have made the following observations. In the same circumstances in which a single strand of 30 SWG. fuses at 32 amperes, a double strand of 36 SWG. fuses at 23 amperes, and a double strand of 34 SWG. fuses at 43 amperes. It would therefore appear that the equivalent required is a double strand of 35 SWG. which presumably would fuse at about 33 amperes, the single strand going perhaps at 16 amperes. When we have your confirmation, we shall be able to put on order a quantity of this wire for this purpose; but it is no use doing so unless it is required. EFC. | ||