Graph comparing coolant performance in a Hawker Fury radiator using water and ethylene glycol mixtures.

Identifier  ExFiles\Box 179b\2\  img239
Date  28th December 1932
  
HAWKER FURY RADIATOR FRONTAL AREA 2.60 FT
No BLANKING
MECCANO HANGAR TILTED 15° NOSE UP
ENGINE KES 1003 T.S. TESTS RUN @ 550 B.P 2500 RPM
COMPARATIVE CURVES USING 100% WATER, 30% ETHYLENE GLYCOL, 50% AS COOLANTS.
CURVE 1

AXIS LABELS:
Y-AXIS: TEMP. °C
X-AXIS: TIME MINS

LEGEND:
50% ETHYLENE GLYCOL OUTLET TEMP
30% ETHYLENE GLYCOL OUTLET TEMP
100% WATER OUTLET TEMP
50% ETHYLENE GLYCOL INLET TEMP
30% E.G. INLET TEMP
100% WATER INLET TEMP

PLOTS:
OIL OUTLET TEMP
OIL INLET TEMP

TABLE 1:
AIR TEMP THRo RAD. TUBES
IN FRONT OF RAD BEHIND RAD RISE
100% WATER 15 36 21
30% E.GLYCOL 15 38 23
50% E.GLYCOL 15 40 25

TABLE 2:
A.S.I IN FRONT 140 M.P.H
BEHIND 120