Rolls-Royce Archives
         « Prev  Box Series  Next »        

Graph comparing coolant performance in a Hawker Fury radiator using water and ethylene glycol mixtures.


Identifier  ExFiles\Box 179b\2\  img239
Date  28th December 1932
  
HAWK(Aero Engine)ER FURY RADIATOR FRONTAL AREA 2.60 FT
No BLANKING
MECCANO HANGAR TILTED 15° NOSE UP
ENGINE KES 1003 T.S. TESTS RUN @ 550 B.P 2500 RPM
COMPARATIVE CURVES USING 100% WATER, 30% ETHYLENE GLYCOL, 50% AS COOLANTS.
CURVE 1

AXIS LABELS:
Y-AXIS: TEMP. °C
X-AXIS: TIME MINS

LEGEND:
50% ETHYLENE GLYCOL OUTLET TEMP
30% ETHYLENE GLYCOL OUTLET TEMP
100% WATER OUTLET TEMP
50% ETHYLENE GLYCOL INLET TEMP
30% E.G. INLET TEMP
100% WATER INLET TEMP

PLOTS:
OIL OUTLET TEMP
OIL INLET TEMP

TABLE 1:
AIR TEMP THRo RAD. TUBES
IN FRONT OF RAD BEHIND RAD RISE
100% WATER 15 36 21
30% E.GLYCOL 15 38 23
50% E.GLYCOL 15 40 25

TABLE 2:
A.S.I IN FRONT 140 M.P.H
BEHIND 120