Page of calculations for a starter motor, detailing conductor conversion formulas.

Identifier  ExFiles\Box 61b\3\  scan0107
Date  13th July 1928
  
X593
6027. 13.7.28.

STARTER MOTOR.

Conductor conversion :-

134000 VC = 1587 T N

V/N = 1587/134000 T/C

= .01184 T/C

otherwise:-

ø = (60 x 10^8 x b x V) / (Z N P) = (10^8 x b x T) / (1.41 Z P C)

i.e. V/N = T / (60 x 1.41 C)

= .01184 T/C

EFC.
  
  