Test log sheet for battery cell, dynamo, and battery voltage readings.

Identifier  ExFiles\Box 54\2\  Scan077
Date  29th June 1930
  
RR 238 (150 BKS.) (SH57. 29-6-30.) MP 224388
ROLLS-ROYCE LTD.
INSTRUCTIONS.
To
Order No.
Customer's No. 19

Table Data:
Headers: No, Battery Cell Volts (Columns 1-6), +, Dynamo (Temps, Volts, Amps), Battery Volts

Row 1:
No: Ex Sabre RRS
Cell Volts: 2.70, 2.70, 2.67, 2.69, 2.69, 2.69
Dynamo Temps: 13-62-75
Dynamo Volts: 17.6
Dynamo Amps: 11.1
Battery Volts: 16.2

Row 2:
No: Ex SPL.1
Cell Volts: 2.34, 2.30, 2.21, 2.34, 2.31, 2.36
Dynamo Temps: 17-47-64
Dynamo Volts: 15.2
Dynamo Amps: 10.1
Battery Volts: 13.9

Row 3:
No: Ex Sabre R {Sir Henry Royce} /R Elswick 3
Cell Volts: 2.87, 2.84, 2.84, 2.90, 2.90, 2.87
Dynamo Temps: 18-59-77/1
Dynamo Volts: 19.1
Dynamo Amps: 12.3
Battery Volts: 17.3

Row 4:
No: SZ.
Cell Volts: 2.83, 2.85, 2.80, 2.78, 2.71, 2.80
Dynamo Temps: 14-54-71/1
Dynamo Volts: 18.5
Dynamo Amps: 12.2
Battery Volts: 16.8

Row 5:
No: SY.
Cell Volts: 2.81, 2.70, 2.81, 2.67, 2.80, 2.88
Dynamo Temps: 13-58-71/11
Dynamo Volts: 18.3
Dynamo Amps: 11.8
Battery Volts: 16.7

Row 6:
No: SX
Cell Volts: 2.65, 2.83, 2.61, 2.81, 2.88, 2.80
Dynamo Temps: 15-59-74/1
Dynamo Volts: 18.2
Dynamo Amps: 11.8
Battery Volts: 16.4

Row 7:
No: SL.
Cell Volts: 2.90, 2.90, 2.62, 2.89, 2.65, 2.69
Dynamo Temps: 16-58-74/1
Dynamo Volts: 18.1
Dynamo Amps: 11.7
Battery Volts: 16.6

Row 8:
No: S4.
Cell Volts: 2.65, 2.91, 2.45, 2.91, 2.63, 2.91
Dynamo Temps: 17-54-71/1
Dynamo Volts: 18.1
Dynamo Amps: 11.9
Battery Volts: 16.5

Extra value in Amps column: 12.0

Signed
This Sheet must be filed on completion of the work.
  
  