Page detailing formulas for calculating volume flow, with variable definitions and notes for ensuring reliable measurements.
Identifier | ExFiles\Box 88\4\ scan0028 | |
Date | 8th September 1933 guessed | |
-7- ∴ Vol flow at (3) = (22.34 K P₁ / √T₁) / (P₃ / RT₃) = 30.35 K T₃P₁ / (P₃√T₁) cu.ft/min. T in ⁰C abs. T₃ " ⁰C abs. P₁ & P₃ "Hg. abs. This is the formula on which all the air flows following have been calculated. - for large nozzle - 2.5" dia. - the constant is 175 instead of 30.35. Note:- For reliable comparison of gas flows through a restriction, it is desirable that the pressure and temperature of the gas should be as nearly the same in each case as possible - hence where possible the pressure difference across valve was kept constant and the air flow measured, rather than the flow being kept constant and the pressure difference measured. For Frank Lee X 1497 | ||