Journal article comparing regulated-input and third-brush input electrical generator systems for battery charging.


Identifier  ExFiles\Box 31\1\  Scan176
Date  1st June 1925
  
Vol. XVI
June, 1925
No. 6
578
THE JOURNAL OF THE SOCIETY OF AUTOMOTIVE ENGINEERS

TABLE 1—COMPARATIVE CURRENT AND VOLTAGE VALUES
Time, Hr. | Average Current, Amp. | Average Potential, Volts | Approximate Number of Watt-Hr. Watts | Approximate Number of Watt-Hr. per Hr.
Regulated Input of Current to the Battery
1 | 22.5 | 14.1 | 317 | 317
2 | 21.0 | 14.5 | 304 | 304
3 | 17.0 | 14.7 | 260 | 260
4 | 13.0 | 14.7 | 191 | 191
5 | 9.5 | 14.7 | 139 | 139
6 | 7.0 | 14.7 | 103 | 103
7 | 5.5 | 14.7 | 74 | 74
Total | | | 1,388 | 1,388

Third-Brush Input of Current to the Battery
1 | 22.0 | 15.0 | 330 | 330
2 | 23.0 | 15.7 | 362 | 362
3 | 23.0 | 15.6 | 358 | 358
4 | 22.5 | 15.2 | 352 | 352
5 | 22.5 | 15.1 | 340 | 340
6 | 22.0 | 15.0 | 330 | 330
7 | 21.5 | 15.0 | 323 | 323
Total | | | 2,395 | 2,395

[Column 1]
it was 2395, showing a difference of 1007 watt-hr.; that is, the third-brush machine delivered about 73 per cent more power in the same time than did the voltage-regulated generator. The two runs were taken on the same battery at approximately the same condition of discharge on starting.
Beyond a certain point, electrical energy cannot be used in charging the battery and represents a direct loss. In his article entitled Finishing Charge Paramount,² W. E. {Mr Elliott - Chief Engineer} Dunn touched on this point as follows:
Should the high charging-rate be continued, a point is reached where part of the current can do no useful work in charging the battery. As the excess energy breaks-down the water into gas and generates heat. The higher the temperature is, the greater the unnecessary wear and tear become. By the breaking-down of the water into its component elements, a process known as "gassing," the bubbles of gas coming out of the plate and rising to the surface erode the active material from the surface of the plate. . . . Therefore, . . . a definite control of the charging rate throughout the charge is required. Such a system should be automatic. . . .
The bearing of the foregoing facts on battery life is obvious, and the actual amount of lost energy is considerable. Assuming a generator efficiency of 50 per cent for both types of generator, simply as an approximate basis of comparison, the power necessary to drive the voltage-regulated generator when delivering its maximum output of 317 watts would be 317 x 1.5 = 476 watts, or approximately 0.64 hp. At the end of the charge, or while running with the battery well up in charge, this would fall to 74 x 1.5 = 111 watts, or 0.15 hp.
For a third-brush machine, the maximum power required would be 362 x 1.5 = 543 watts, or about 0.71 hp. Note that the power required is sustained, the minimum falling to only 323 x 1.5 = 485 watts, or about 0.64 hp.
Considering the two tests of equal duration, the inputs were approximately 1388 and 2395 watt-hr., a difference of 1007 watt-hr. or about 1.35 hp-hr. Translated into dollars and cents of cost, the yearly saving in power alone is of material importance on high-capacity continuous-service applications.
The voltage-regulated system is automatic, but the out-
² See Electrical World, Nov. 29, 1924, p. 1162.

[Column 2]
put of the current-regulated system usually is determined by the position of a third brush on the generator and by battery condition. The two types of equipment are designed for different purposes. The operation of the voltage-regulated system is different from the operation of the current-regulated system, as will appear from the following comparison.

THE TWO ELECTRICAL SYSTEMS COMPARED

When connected to the battery, the generator in the current-regulated system delivers a fairly uniform current at all times. The voltage of the generator is controlled by the voltage of the battery. In the case of a discharged battery, for example, a 12-volt battery, the voltage would be about 12 volts. To charge this battery, it is necessary to have a higher voltage than that of the battery itself. The predetermined amount of current for which the generator has been set will not flow into the discharged battery unless the generator voltage is higher than the battery voltage.
As the current is forced into the battery, the voltage of the battery rises and the generator voltage rises correspondingly above that of the battery to a point sufficient to maintain approximately the same charging rate. When the battery is fully charged, it registers about 2½ volts per cell, or a total of approximately 15 volts. The generator voltage may then be about 18 or 19 volts at the generator, considering the line losses, to get the same current or charging rate into the battery. The generator voltage might need to reach 20 volts, owing to the resistance in the line and the battery. In a current-regulated system, it is essential that the generator and the battery be connected securely when the generator is operating, so as to prevent too great a rise in the generator voltage. Open circuits, corroded battery terminals, insufficient water in the battery and other faults will cause a rise in the voltage of the generator which, if permitted to continue, will result in difficulties.
In the voltage-regulated system, assuming a voltage-regulated generator set for approximately 15.1 volts and that it is connected to a discharged 12-volt storage-battery, the battery registering 12 volts, the maximum current is determined by the design of the system and this is determined at the time of manufacture. The voltage of the battery rises, due to charging, and the generator output drops off until the generator voltage is about equal to that of the battery voltage; after this, only a trickling charge will flow from the generator to the battery.
Voltage regulation will build-up a battery quickly and protect it from overcharge, due to the fact that the voltage of the battery when charged is about equal to the voltage of the generator. Unlike the current-regulated generator, the voltage regulated-generator can be operated when connected to or disconnected from the battery. Since the voltage of the generator is controlled by the regulator, the lamps can be operated directly from the generator. This feature of voltage regulation assures light while the vehicle is in operation, whether the storage-battery is connected or not. The life of the battery is prolonged and the electrolyte does not decompose so rapidly as when being charged continuously by a current-regulated generator. In motorcoach service, where no two runs are exactly alike and where either traffic or highway conditions are severe, the advantage of the voltage-regulated system is recognized. Operation in city service, with many stops and starts or with intermittent periods of idling and full acceleration, formerly resulted in batteries receiving a charge insufficient.
  
  