Water circulation test results for a Phantom water pump and S.S. radiator.

Identifier  ExFiles\Box 149a\1\  scan0042
Date  8th May 1933 guessed
  
WATER CIRCULATION TESTS.
PHANTOM WATER PUMP AND S.S. RADIATOR.

| PUMP SPEED RPM. | 16°C | | 90°C | | 95°C | |
|---|---|---|---|---|---|---|
| | PRESS DIFF INS.HG. | WATER FLOW GLS/MIN. | PRESS DIFF INS.HG. | WATER FLOW GLS/MIN. | PRESS DIFF INS.HG. | WATER FLOW GLS/MIN. |
| 2000 | 2.8 | 14.42 | 3.4 | 15.91 | 1.8 | 11.59 |
| 2500 | 5.8 | 20.79 | 4.2 | 17.69 | 2.0 | 12.21 |
| 3000 | 10.0 | 27.25 | 3.8 | 16.82 | 2.0 | 12.21 |
| 3500 | 12.8 | 30.85 | 3.6 | 16.38 | 2.0 | 12.21 |

# Boiler tank collapsed owing to depression.

Q(GLS/MIN) = 8.64 √H"

Initial Pumping Speeds.
At 16°C Press. Diff. commences at 900 R.P.M.
At 90°C " " " " 1350 R.P.M.
At 95°C " " " " 1350 R.P.M.

--------------

Time to empty radiator through 1½" bore pipe :-
After 16 secs. flow dropped rapidly from full bore,
last trickle after 33 secs.

--------------
  
  