Standard volt-ampere characteristics and resistance limits for starter motor batteries, leads and cables.

Identifier  ExFiles\Box 61b\3\  scan0142
Date  26th August 1921
  
X543 6027

26.8.21.

X.543. STANDARD VOLT-AMPERE CHARACTERISTIC OF BATTERY AND LEADS FOR STARTER MOTOR TESTS. X.664.

Amperes. Volts.

50 11.0
75 10.5
100 10.0
125 9.5
150 9.0
175 8.5
200 8.0
225 7.5
250 7.0

Limits ± .1

X.543. X.664. STARTER MOTOR CABLE AND BATTERY RESISTANCE LIMITS.

Cable .005 ohm.
Battery .015 ohm.
Total .02 ohm.

Loss of volts due to 100 amperes = 2
agreeing with specified volt drop.