Production inspection and test specification for a starter main switch unit.


Identifier  ExFiles\Box 168a\2\  img263
Date  30th November 1936
  
SPECIFICATION NO. ELC.5/B
30.11.36.

STARTER MAIN SWITCH UNIT

SPECIFICATION OF PRODUCTION INSPECTION & TEST
USED ON PHANTOM III, 25/30 HP. AND BENTLEY

TO DRAWINGS:- General arrangement D.100208
Main coil arrangement D.74174
Resistance coil arrangement D.74175.
Copper contact stiffener D.75813.

I. GENERAL INSPECTION

(1) Ascertain that the copper laminated contacts of the main switch unit offer a satisfactory bedding in correct sequence on the copper contact plate of the main switch pillar. This bedding is very important.

(2) Ascertain that the copper flexible connections on the switch shews no sign of fraying.

(3) Examine also the carbon contacts for correct surface bedding, when the switch is depressed by a force applied to the main lever (armature). It is important that the switch be not depressed by pressing the top carbon contact arm. It should also be ascertained that the carbons are not cracked or chipped through tightening the securing clamp.

(4) It should be verified particularly that all screws upon which electrical contacts depend are thoroughly tight.

(5) Inspect generally the small resistance bobbin which is connected in parallel with the main switch operating coil.

(6) It should be verified that there is not more than .004" clearance between the main switch armature and main contd.
  
  