Analysis of fuel pump discharge, spill, and delivery curves related to the configuration of suction chamber holes.


Identifier  ExFiles\Box 179b\3\  img097
Date  1st February 1932
  
Hs {Lord Ernest Hives - Chair} /Ud.6/ATL.2.32 contd.

-7-

From the figures set out in Table 2 it will be seen that the discharge is but slightly affected by the position of the unplugged suction hole. When this hole is opposite the supply pipe the delivery falls slightly at all speeds but at present no explanation of this can be offered. The spill shows much greater variation with number and position of suction chamber holes. With all six holes open at 1000 R.P.M. it is .079 ccs/cycle, but with holes 2, 3 & 4 and with 2 holes open, it falls to about .045 ccs/cycle, while Hole 1, opposite supply pipe, gives a larger spill. At the lowest speed (336 R.P.M.) the spill varies with hole position in precisely the same way as at 1000 R.P.M.

The sum of discharge and spill is greatest at all speeds with the 6 holes open, but for the other arrange-ments, varies but little with speed.

The theoretical discharge at 1000 R.P.M. allowing for effect of compressibility of fuel oil and the unloading valve capacity calculated as shown on page 3 on previous report (Hs {Lord Ernest Hives - Chair} /Ud.7/KT6.1.33), is 0.462 ccs/cycle. It will be noted that the sum of the discharge and spill is greater than this in all cases. This suggests that there is a certain amount of direct leakage from suction chamber to spill chamber.

The spill at the lowest speed exceeds that at 1000 R.P.M. which is consistent with there being direct leakage from suction to spill chamber.

At the lowest pump speed (336 R.P.M.) the rate of discharge from the nozzle with static setting of 3000 lbs/sq.in. exceeds the rate of plunger displacement and the discharge is therefore theoretically discontinuous.

Referring now to the delivery curves (Figs. 2, 5, 13, 10, 17 14), these all show the same characteristic of falling away from the ideal straight line at the upper and lower speeds. This tendency is common to most fuel injection pumps and the falling away at higher speeds is generally attributed to imperfect filling of the pump chamber and at lower speeds to increase in leakage past the pump plunger, more time being available for such leakage to take place.

The number and position of the suction chamber holes effect the form of the delivery curve to some slight extent. It departs most from the ideal straight line for hole No.1 and the other curves vary but little. This may also be seen from Table 2.
  
  