Customer complaint and test department findings for a faulty dynamo and distribution box on a 20 HP Chassis G.H. 66.


Identifier  ExFiles\Box 47\4\  Scan181
Date  8th May 1924
  
R.R. 199 (150T) (SD570 19-7-17) MP180805
X 4863.

BY {R.W. Bailey - Chief Engineer} /HM {Capt. W. Hallam - Head Repairs} /2/K. 8.5.24.

EFC. {E. Fowler Clarke - Electrical Engineer}
----

20 HP CHASSIS G.H. 66.
----------------------

The customer of the above chassis has recently complained that his dynamo would not charge also that the distribution box was faulty, therefore new parts were sent to him and the parts complained of have new been returned.

The test department have examined the parts and they report that the dynamo has been damaged by excessive heat at the commutator due to running on an open circuit, when the dynamo was charging, also the control brush shows signs of arcing.

Regarding the distribution box which has been damaged due to excessive heat which has melted all the varnish out of the shunt coil, this they consider is due to running on an open circuit, when the dynamo was charging possibly on account of the main fuse being at fault.

[Handwritten note 'Battery' with an arrow pointing to the word 'connection'] We agree with EP {G. Eric Platford - Chief Quality Engineer} "s remarks, and we think also that possibly the cause may have been due to a faulty connection battery [the word 'battery' is struck through], but if you will kindly send your boy to the D.O. we will hand over the dynamo and distribution box in order that you may examine same and let us have your report.


BY {R.W. Bailey - Chief Engineer} /HM. {Capt. W. Hallam - Head Repairs}
[Signature]

[Stamp: RECEIVED 24 MAY 1924]
  
  