Calculations comparing the hole area of various ebonite separator samples.

Identifier  ExFiles\Box 54\5\  Scan038
Date  16th October 1925
  
X4651

16.10.25.

HOLE AREA OF EBONITE SEPARATORS.

The original thinner sample, representing (.4 mm) standard, is 100 x π/4 x (.068)^2 = .363 .

The thicker (1 mm) sample referred to on sheet dated 10.6.25 =
= 137 x π/4 x (.055)^2 = .326

The new .6 mm. sample now proposed
= 55.3 x π/4 x (3/32)^2 = .382

Thus the 1 mm. thick sample has 11% more hole area than the present standard, and the new proposed standard of .6 mm. will contain 17% more hole area than the present standard.

____

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  