Rolls-Royce Archives
         « Prev  Box Series  Next »        

Graph of vapor lock tests on an AC combination fuel pump and vacuum booster on a 1935 Pontiac Six.


Identifier  ExFiles\Box 149\4\  scan0281
Date  1st July 1935
  
VAPOR LOCK TESTS ON AC COMBINATION FUEL PUMP AND VACUUM BOOSTER ON 1935 PONTIAC SIX.

Y-AXIS: REID VAPOR PRESSURE OF GASOLINE
X-AXIS: ATMOSPHERIC TEMPERATURE °F

SERIES 1: COMBINATION WITH FUEL PUMP BELOW BOOSTER
INSULATING GASKET BETWEEN FUEL PUMP AND CRANKCASE - FUEL PUMP SHIELDED
BORDERLINE VAPOR LOCK AT 60-65 DURING ACCEL. ON LEVEL FOLLOWING 5 MIN. STOP WITH IGN. OFF. ALSO 4-8 MILE LOSS IN MAX. SPEED ON 11% HILL
NO VAPOR LOCK FOUND IN ANY TEST

SERIES 2: COMBINATION WITH FUEL PUMP ABOVE BOOSTER
NO INSULATING GASKET NOR RADIATION SHIELD
MOMENTARY VAPOR LOCK ON 11% HILL AFTER 5 MIN STOP WITH IGN. OFF
GASOLINES EQUIV. 9.0 LBS. AT 100° F. {Mr Friese}

SERIES 3: 1935 PRODUCTION
MOMENTARY CUTTING OUT ON 11% HILL AFTER 5 MIN. STOP WITH IGN. OFF

DATA POINTS: 15.2, 10.1, 7.2
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).