Issues with a fan testing rig and proposing a chain drive modification to allow for more efficient testing of fan belts.
| Identifier | ExFiles\Box 75\3\ scan0160 | |
| Date | 3rd March 1925 | |
| To RHC. {R. H. Coverley - Production Engineer} from Hs {Lord Ernest Hives - Chair} /Rm. {William Robotham - Chief Engineer} 43438 Hs {Lord Ernest Hives - Chair} /Rm {William Robotham - Chief Engineer} 1/LG3.3.25. FAN TESTING RIG. We have tried testing some fan belts on the new rig. We find that we cannot test 4 belts at once. The reason for this is that for any serious strain to be thrown upon the fan belt, it is necessary for the fan to be revolving at about 2,000 r.p.m. The H.P. required to drive the 40/50 fan at this speed is 3.15 HP. The total h.p. required is therefore 12.6 HP. The motor does not appear to be capable of transmitting this H.P. In addition, the leather belt from the motor stretches very rapidly and will not drive the 4 fans at above 1400 r.p.m. for any length of time. As our simplest method of ascertaining the efficiency of a belt is to measure the amount of stretch in terms of reduction in fan speed, it is rather important that the initial drive shall provide a constant speed so that we shall only have one variable to deal with. It would therefore appear that if you could provide a short Renolds Chain Drive from the motor to the fan rig, we could then test two belts at once, if not more. Hs {Lord Ernest Hives - Chair} /Rm. {William Robotham - Chief Engineer} | ||