Continued test procedures for a relay switch unit.

Identifier  ExFiles\Box 64\3\  scan0198
Date  1st March 1925
  
X8650

contd :- -4- EFC4/E5.3.25.
----------

(5) Now verify that the main spring tension (combined rating and set) is such that with a current of 3.0 amperes passing through the fine winding, a load of at least 3.0 lbs. measured at the core on a spring balance is required to break contact of the lower contacts.

(6) Whilst still warm from test (5) an alternating voltage of 205 shall be applied, through a lamp, between the windings (both) and the base, for one minute without break-down.

(7) The final test of this relay switch unit is to consist of testing under approximate operating conditions as described in Section III.


EFC.
  
  