Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Performance chart and specifications for a seamed tube oil cooler.

Identifier  ExFiles\Box 131\1\  scan0234
Date  6th December 1935
  
SEAMED TUBE OIL COOLER.
OIL TO WATER HEAT TRANSMISSION
AREA FOR WATER FLOW = 1.010 ☐"
NO. OF TUBES = 7
NO OF PASSAGES FOR OIL (SERIES)=6
NO. OF LOOPS DEEP = 8
DEPTH OF ELEMENT = 2 1/8"
COOLING SURFACE TO WATER = .565 ☐ft
COOLING SURFACE TO OIL WIRE ONLY = 1.935 ☐ft
HEIGHT OF ELEMENT 2 5/8"
ACTUAL TEMPS. ON TRIALS - WATER INLET TEMP.= A.70°F B.130°F
-OIL MEAN TEMP. = A.170°F B.190°F
OIL FLOW = 20.2 LBS/MIN.
MOBILOIL 'A' USED.
DIAGRAMMATIC ARRGT. OF OIL FLOW.
Graph Y-Axis: B.T.U.s/HOUR/100°F TEMP. DIFF.
Graph X-Axis: WATER FLOW. LBS/MIN.
Graph Curves: A, B
Signature: Litten
  
  


Copyright Sustain 2025, All Rights Reserved.    whatever is rightly done, however humble, is noble