The insufficient sensitivity of the thermostat controlling the radiator shutters.

Identifier  ExFiles\Box 82\1\  scan0328
Date  13th December 1933
  
To Hs.{Lord Ernest Hives - Chair}

x41/Bw

Hotel de France.
Chateauroux.
Indre.
13.12.33

I. B. IV.

Re Radiator Shutters and Thermostat

We find that the load wanted by the thermostat when fully extended is 5 lbs at the end of the lever attached to the radiator shutters, but it requires 85°C in the radiator to fully extend. At 75°C in the radiator it is only half open and is exerting a force of approx 3 lbs. Our trouble therefore is that the thermostat is not sensitive at the temperature we require for normal running.

G H Hancock