Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Report comparing the performance and weight of Edison cells against C.A.V. and Exide cells.

Identifier  ExFiles\Box 1\7\  B001_X15 20 46 50 59-page211
Date  13th March 1913
  
AW/E10/L13313
Mr Royce

X.50

March 13th 1913.

X.50. Report on Edison Cells. X 560

I have had Edison cells in constant use since previous report (26/11/12) and I find they give good results on the coil system, having had as much as 47 amp. hours work out of them. I have had 58 amp. hrs out Exides (40 amp. hr cells)

The Edison cells behave extraordinary when left standing. I have had the experience of completely running down the cells to .5 volts and left standing 10 hours and recovering themselves to discharge again 20 amp. hours (7 amp. discharge) This same cell acted in this way 3 times before discharging.

The C.A.V. cells are inclined to drop when left standing.

I have not taken any discharge curves of C.A.V.'s yet, having to rig up a board for charging same so that I will know what is put into them.

All reports are from Test Garage charging.

Weights re cells

Edison's cells only, no box. - 12 volts 16 lbs 14 ozs.

C.A.V's cells only, no box.(120 amp.hr) - 12 volts 72 lbs 12 ozs.

Edison cells including tray & fittings (40 amp hrs) - 12 volts 28 lbs 4 ozs.

Copy of previous report sent in Nov. 26th 1912 :-
  
  