Comparing water temperatures and water pump delivery between EAC 'V' series and 40/50 cars.


Identifier  ExFiles\Box 24\4\  Scan317
Date  3rd March 1925
  
R.R. 493a (50m) (D.B. 175 25-9-24) J.H.D.
-2-
Expl. No.
REF: Hs {Lord Ernest Hives - Chair} /Rs {Sir Henry Royce's Secretary} /L631.3.25.
EXPERIMENTAL REPORT.
COMPARISON EAC. AND 40/50 CARS.

30 m.p.h. | 40 m.p.h.
EAC. 'V' series. | 28.8°C | 29.9°C
40/50 21 h.p. | 20.5°C | 25.3°C

E.A.C. WATER PUMP DELIVERY.
These tests were carried out with venturi fitted in bottom water pipe of 44-PK. Standard EAC. 'V' series water system and radiator.
Engine run light - water temp. 50°C - 80°C

Engine R.P.M. | Difference in levels of two limbs. | Water flow galls/min. | 40/50 flow galls/min.
500 | .26" | 6.85 | 5.5
750 | .66" | 10.92 | 8.3
1000 | 1.30" | 15.31 | 10.5
1250 | 2.00" | 19.00 | 13.0
1500 | 2.90" | 22.85 | 15.0
1750 | 4.10" | 27.20 | 18.0
2000 | 5.30" | 30.95 | 21.0
2250 | 6.60" | 34.60
2500 | 8.05" | 38.20
2750 | 10.00" | 42.50

Law of venturi 13.46 √h. {Arthur M. Hanbury - Head Complaints}
  
  