Photographic example of extreme wear on a Hypoid, Rear-Axle Pinion due to lubricant type.


Identifier  ExFiles\Box 114\1\  scan0075
Date  11th January 1937 guessed
  
Operated for approximately 5,000 miles, without wear, on a powerful lead-soap active-sulfur extreme-pressure lubricant. Wear shown in photograph (approximately one-third of original tooth thickness) occurred in less than 300 miles of operation, on a mild sulfur-saponifiable lubricant.

Hypoid, Rear-Axle Pinion.

Fig. 22
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).