Returning unsuitable thermometers from Peto & Radford for measuring accumulator temperatures and suggesting an alternative supplier.
| Identifier | ExFiles\Box 164\2\ img070 | |
| Date | 26th January 1942 | |
| 6021 10000 To BJJ/HC. from Ra/EC. Ra/EC.3/MT.26.1.42. THERMOMETERS FOR MEASURING ACCUMULATOR TEMPERATURES. With reference to the attached letter from Peto & Radford, we have tested the thermometers which they have supplied and find that they are quite unsuitable for our purpose. We return them herewith. When immersed 1 1/2 inches, they read correctly. However, in our case, the maximum immersion depth is only half an inch, and this causes the above thermometers to read inaccurately, giving a maximum error of 6 degrees with a rising temperature, and a low reading with a maximum of 3 degrees with a falling temperature. We suggest you try Chloride Electrical Storage Co. Ra/EC. | ||