Returning unsuitable thermometers from Peto & Radford for measuring accumulator temperatures and suggesting an alternative supplier.


Identifier  ExFiles\Box 164\2\  img070
Date  26th January 1942
  
6021
10000

To BJJ/HC. from Ra/EC.

Ra/EC.3/MT.26.1.42.

THERMOMETERS FOR MEASURING ACCUMULATOR
TEMPERATURES.

With reference to the attached letter from Peto & Radford, we have tested the thermometers which they have supplied and find that they are quite unsuitable for our purpose. We return them herewith.

When immersed 1 1/2 inches, they read correctly. However, in our case, the maximum immersion depth is only half an inch, and this causes the above thermometers to read inaccurately, giving a maximum error of 6 degrees with a rising temperature, and a low reading with a maximum of 3 degrees with a falling temperature.

We suggest you try Chloride Electrical Storage Co.

Ra/EC.
  
  