Rolls-Royce Archives
         « Prev  Box Series  Next »        

Performance graph and specifications for a New Mark V Radiator.


Identifier  ExFiles\Box 149a\2\  scan0392
Date  1st June 1941
  
NEW MARK V RADIATOR

FRONTAL AREA = 3.24 sq ft
FRONTAL ASPECT = 23 7/8" HIGH x 19 5/8" WIDE = 3.26 sq ft
COOLING SURFACE =
Nº OF WATER PASSAGES = 54
DEPTH OF BLOCK = 56 MM. (2.2")

CONSTANT WATER FLOWS (A) 34.5 GALLS/MIN.
(B) 20.0 GALLS/MIN.

AIR INLET 60°F
WATER MEAN 160°F

L 616 B1.100

Graph Labels:
STATIC DIFFL IN AIR PRESS. INS. WATER. MATRIX TRUNKED FORE AND AFT.
AIR FACE VELOCITY MILES PER HR
AIR FLOW CU.FT/MIN. CALCULATED AT 60°F AND 29.9" Hg.
H.P. DISSIPATED / 100°F TEMP. DIFF. (AIR INLET TO WATER MEAN)
H.P. DISSIPATED
AIR PRESSURE AT WATER TEMP OF 160°F
(A)
(B)

RR/6141
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble