Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Adjustment instructions for the Bleriot Phi cutout instrument.

Identifier  ExFiles\Box 48\3\  Scan263
Date  16th July 1921
  
R.R. 558a (100 T) R.H. 723. 10-12-20. G 2747

X.4215

16.7.21.

X.4215 - BLERIOT PHI CUTOUT - ADJUSTMENT OF INSTRUMENT.

(1) Adjust back air gap until, with the instrument cold, no inherent vibration takes place at the cutting in voltage at which the instrument is working at the time.

(2) Get the instrument into a warm condition, and, by altering the tension of the main spring, adjust the cutting in voltage to the neighbourhood of the top limit of 14.2 (without altering the back air gap). It is probable that no vibration will now take place at the cutting in point with the instrument in this condition. If it does, very slightly reduce the back air gap to overcome this and again set the main spring to suit the cutting in voltage.

(3) The instrument in a hot condition should now comply, or very nearly comply with our specification.

(4) When the instrument is again cold, take figures in cold condition. It is expected that these will be O.K. or very nearly so.

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  