Rolls-Royce Archives
         « Prev  Box Series  Next »        

Calculations and suggestions for pole windings, including cross-sectional area and turns.


Identifier  WestWitteringFiles\Q\2April1927-June1927\  203
Date  1st May 1927 guessed
  
-7- Contd.

The cross sectional area of this strip

= .00815 / .985 = .00827"

or as much greater than this as space will allow after getting
in 36 turns of 17 SWG. teazer winding per pole.

Suggest in the first instance we try -

(1) On each of the four poles 36 turns of 17-SWG. teazer winding plus 3½ turns of main of as much section as possible.

and (2) On each of two opposite poles as many 17-SWG. teazer turns as possible, and on the other two poles 7½ turns of main winding of as much section as possible.

_______

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).