Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Graph showing oil cooling dissipation and pressure drop for a specific tube configuration in a free air stream.

Identifier  ExFiles\Box 149a\2\  scan0308
Date  23th August 1935
  
OIL COOLING
CX.{Major Len W. Cox - Advertising Manager}107/2.
DISSIPATION OF TUBE C(o/16)
ONE TUBE IN FREE AIR STREAM
FORMULA
22/3/8/19/1.814/23.1/43.3/1/8 No 30
BUTT INTERNAL WOUND 22G COPPER.
OIL MEAN TEMP = 170° F
AIR INLET = 70° F
AIR VELOCITY = 1,200 FT/MIN
OIL FLOW = 20.5 LBS/MIN (MOBILOIL A)
Left Y-Axis: OIL PRESSURE DROP LBS/IN²/FT. RUN.
Right Y-Axis: B.T.U.'S. PER. HR. PER. FT. RUN. AT. 100° T.D. AIR. INLET. TO. OIL. MEAN.
Top X-Axis: AIR VELOCITY FT/MIN
Bottom X-Axis: LBS/MIN/TUBE.
Graph Lines:
DISSIPATION TO OIL FLOW
DISSIPATION TO AIR VELOCITY
OIL PRESSURE DROP TO FLOW
Diagram: 7"RAD, 3/4", 1/2"
Signature: EWS
  
  


Copyright Sustain 2025, All Rights Reserved.    whatever is rightly done, however humble, is noble