Comparison of efficiencies for the STD 40/50 RR and E.A.C-1 configurations, including data on thermal efficiency and valve timing.
Identifier | WestWitteringFiles\K\November1923\ Scan44 | |
Date | 12th July 1923 guessed | |
PAGE 5. COMPARISON OF EFFICIENCIES OF STD. 40/50 RR. & E.A.C-1 WITH THE 'AIR STANDARD' EFFCY: 40/50 RR. Comp: ratio = 3.99 E.A.C.1 " " = 4.6 'Air standard' = 1 - 1/R^(r-1) --- TABLE 1: | R.P.M. | Indicated Thermal Efficiency % | Indicated thermal efficiency X 100 / standard efficiency % | |---|---|---|---|---| | | 40/50 RR. | E.A.C.1. | 40/50 RR. | E.A.C.1. | | 500 | 21.34 | ---- | 50.25 | ---- | | 600 | ---- | 27.33 | ---- | 59.8 | | 750 | 21.24 | 27.56 | 50.0 | 60.4 | | 1000 | 23.69 | 27.31 | 55.8 | 59.8 | | 1250 | 24.00 | 30.05 | 56.5 | 66.75 | | 1500 | 24.74 | 29.49 | 58.2 | 64.6 | | 1750 | 25.50 | 29.26 | 60.0 | 64.0 | | 2000 | 25.10 | 29.52 | 59.1 | 64.7 | --- TABLE 2: AIR STANDARD EFFICIENCY. | 40/50 RR. R = 3.99 | E.A.C.1. R = 4.6 | |---|---| | .4251 | .4569 | --- VALVE TIMING USED. Diagram showing: IN. OP. 2° EX. CLO. 4° IN. CLO. 37° EX. OP. 48° Timing taken with .010" tappet clearance. 110° Camshaft. | ||