Experiments on measuring Phantom cylinder wall temperatures.

Identifier  WestWitteringFiles\P\October1926-November1926\  Scan020
Date  1st October 1926
  
To R.{Sir Henry Royce} from Hs{Lord Ernest Hives - Chair}/ACL.
c. to BJ. Wor.{Arthur Wormald - General Works Manager}
c. to RG.{Mr Rowledge} E.{Mr Elliott - Chief Engineer}
c. to DA.{Bernard Day - Chassis Design} BY.{R.W. Bailey - Chief Engineer}
c. to CY.

ORIGINAL

Hs{Lord Ernest Hives - Chair}/ACLL/LGS.10.26.

X9050
X1643

PHANTOM CYLINDER WALL TEMPERATURE.

During some experiments in connection with over-oiling we took a record of the temperature at various parts of the cylinder wall and skirt. The temperatures were on the outside wall - not the bore side.

The readings were made by means of nickle-iron thermo couples - the ends being brazed together and soldered to the cylinder to ensure good thermal contact. The nickle wire only was insulated and when used in the upper part of the bore was encased in a rubber tube led through the water space.

For this type of work we prefer to use a return iron wire to the cold junction instead of employing the engine itself because unless the wire is of the same composition as the part of the engine with which it is connected, we are liable to obtain errors in the readings, also by means of a direct return the complete couple can be, and was, calibrated in heated oil - the calibration allowing for whatever resistance the wire had and which would not be known when using the engine as 'earth'.

The cold junction was provided by means of cold water flask and a special Weston Galvanometer was employed.

The following sketch shows the apparatus we used :-

contd :-
  
  