The results of heating and freezing tests on various condensers.

Identifier  ExFiles\Box 52\3\  Scan154
Date  12th July 1923
  
R.R. 493A (40 H) (SL 42 12-7-23). J.H.D.
EXPERIMENTAL REPORT. -2- Expl. No. 4430 REF: F.C.4.
Contd.

signs of rising.

The ratios of the capacity observed
at the end, i.e. 16°C, to that observed at the beginning,
3.5°, were respectively:-

Condenser No. Ratios.
32 1.21
613 1.16
741 1.17
Bosch 1.19

The results, together with other relevant
details of the condensers, are given tabulated below:-

No. of Condenser. 32. 613 741 U.S.A. Bosch. Remarks.

K before heating test. .182 18°C .399 18°C .344 18°C .710 18°C
K after heating test. .305* 18°C .573 18°C .410 18°C .790 18°C * Value after second heat test.
K before first freezing test. .270 15.5°C .625 15.5°C .418 15.5°C -
K after first freezing test. .265 15°C .610 15°C .415 15°C -
K before second freezing test. .240 14°C .578 14°C .402 14°C .766 14°C
K after second exposure at outside temperature .200 3.5°C .520 3.5°C .358 3.5°C .672 3.5°C
K at the end of second freezing test. .242 16°C .601 16°C .418 16°C .800 16°C
K 24 hours later. .230 16°C .590 16°C .410 16°C .776 16°C

Contd.
  
  