Test results for plug voltage with varying plug gaps and water temperatures.

Identifier  Morton\M13.2\  img012
Date  17th December 1930
  
-3-
EFG1/AD17.12.30 contd.

(b) Plug gaps .025" Water temperature 95 to 100°C.
Cylinder No. Plug voltage
1 5300
3 6020
6 4700

(c) Plug gaps .030" Water temperature 70°C.
Cylinder No. Plug voltage
1 4700
2 4820
4 6600
5 6020
6 5920
7650
Average maximum voltage per plug 5950.

(d) Plug gaps .030" Water temperature 95 to 100°C.
Cylinder No. Plug voltage
1 3900
3 5300
6 5400

These results shew that the plug voltage with .025" and .030" gaps is about the same. We can only explain this by the fact that the gap setting was very critical and that the plugs in the .030" case may have been hotter. With the plugs very hot there is a voltage reduction of about 15%.

20/25 HP. Chassis.
(a) Plug gaps .020" Water temperature 70°C.
Cylinder No. Plug voltage
1 5920
2 6020
3 7200
4 6600
5 6300
6 5920
Average maximum voltage per plug 6330.
  
  