Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Series of performance graphs for Phantom II front dampers under various test conditions.

Identifier  ExFiles\Box 16\4\  Scan235
Date  5th January 1931 guessed
  
SHEET 2 P.II. FRONT DAMPERS

1. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESSURE. .025" DIA. AIR VENT. STD. LIFT 3/16". H.P. VALVE DRILLED .032" DIA. 450 R.P.M. 1" STROKE. 25°C. Graph values: 0.80", 52.3%. Y-Axis: 154 LB/D".
1. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. HIGH PRESSURE. .025" DIA. AIR VENT. STD. LIFT 3/16". H.P. VALVE DRILLED .032" DIA. 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.11", 106.5%. Y-Axis: 154 LB/D".

2. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESS. .025" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 0.66", 45.9%. Y-Axis: 154 LB/D".
2. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. HIGH PRESS. .025" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.10", 113.5%. Y-Axis: 154 LB/D".

3. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESS. .025" DIA. AIR VENT. STD. LIFT 3/16". VALVE COVERS CHANGED OVER, LEAK ON H.P. STROKE. 450 R.P.M. 1" STROKE. 25°C. Graph values: 0.57", 41.7%. Y-Axis: 154 LB/D".
3. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESSURE. .025" DIA. AIR VENT. STD. LIFT 3/16". VALVE COVERS CHANGED OVER. LEAK ON H.P. STROKE. 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.23", 113.5%. Y-Axis: 154 LB/D".

4. LOW PRESSURE: S.S. A.C.D. 90/100 LB. LOW PRESSURE. .025" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 0.58", 39.4%. Y-Axis: 154 LB/D".
4. HIGH PRESSURE: S.S. A.C.D. 90/100 LB. HIGH PRESSURE. .025" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.5", 103%. Y-Axis: 154 LB/D".

5. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESS. .055" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 1.04", 65.2%. Y-Axis: 154 LB/D".
5. HIGH PRESSURE: S.S. A.C.D. 70/80 LBS. HIGH PRESS. .055" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.06", 102.5%. Y-Axis: 154 LB/D".

6. LOW PRESSURE: S.S. A.C.D. 70/80 LOW PRESS. .093" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 1.11", 69.7%. Y-Axis: 154 LB/D".
6. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. HIGH PRESS. .093" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.09", 107%. Y-Axis: 154 LB/D".

7. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESSURE. .156" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 1.20", 74.1%. Y-Axis: 154 LB/D".
7. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. HIGH PRESSURE. .156" DIA. AIR VENT. STD. LIFT 3/16". 450 R.P.M. 1" STROKE. 25°C. Graph values: 2.07", 106%. Y-Axis: 154 LB/D".

8. LOW PRESSURE: S.S. A.C.D. 70/80 LB. LOW PRESSURE. .025" DIA. AIR VENT. 3/16" LIFT. .187" DIA. REFILL HOLE. "YANKEE TYPE". 4" STROKE. 25°C. VARIOUS SPEEDS. Graph details: 140 R.P.M., 120, 100, 80, 60, 40, 20. STATIC LOAD. Load values: 131 LB, 127 LB, 114 LB, 100 LB, 87.5 LB, 79 LB, 70 LB. Y-Axis: 154 LB/D". Note: EQUIVALENT BALL PIN LOAD = 87.5 LB / IN DIAGm.
8. HIGH PRESSURE: S.S. A.C.D. 70/80 LB. HIGH PRESSURE. .025" DIA. AIR VENT. 3/16" LIFT. .187" DIA. REFILL HOLE. "YANKEE TYPE". 4" STROKE. 25°C. VARIOUS SPEEDS. Graph details: 140 R.P.M., 120, 100, 80, 60, 40, 20. STATIC LOAD. Load values: 157 LB, 135 LB, 127 LBS, 114 LBS, 98.5 LBS, 85 LB, 75 LB. Y-Axis: 154 LB/D". Note: EQUIVALENT BALL PIN LOAD = 87.5 LB / IN DIAGRAM.
  
  


Copyright Sustain 2025, All Rights Reserved.    whatever is rightly done, however humble, is noble
An unhandled error has occurred. Reload 🗙