Test results for inherently controlled chassis dynamos.

Identifier  WestWitteringFiles\G\June1921\  Scan97
Date  3rd June 1921
  
I.3698 - INHERENTLY CONTROLLED CHASSIS DYNAMO
DYNAMO TEST RESULTS
3.6.21.

TABLE HEADERS:
- Date of Test
- Dynamo. Name. Type. No.
- Ambient temp. (C°) (Columns: Initial, Final)
- FIELD TEEF: Ohms hot from by increase of resistance (Columns: Initial, Final)
- Rotation speed copper (Columns: Initial, Final)
- Time hours (Columns: Initial, Final)
- Time to final condition Hours
- Balancing speeds before and after test
- Remarks

TABLE DATA:

Row 1:
- Date of Test: 22.11.20
- Dynamo: Rotex. AT.12 593
- Ambient temp (Initial): 11.5
- Field Teef (Initial/Final): 81 / .103
- Rotation speed copper (Initial/Final): 85.5 / 87.5
- Balancing speeds (before/after): 345 / 450
- Remarks: 9 amps. not maintained. Final amps = 8.4

Row 2:
- Date of Test: 23.12.20
- Dynamo: Lucas E 575. R 215A
- Ambient temp (Initial): 19
- Field Teef (Initial/Final): 68 / 117
- Rotation speed copper (Initial/Final): 49 / 98
- Time hours (Initial/Final): 950 / 1270
- Time to final condition: 5.0
- Balancing speeds (before/after): 610 / 725
- Remarks: 9 amps. maintained through out test.

Row 3:
- Date of Test: 27.12.20
- Dynamo: Smith 2D (4)
- Ambient temp (Initial): 13
- Field Teef (Initial/Final): 68 / 94
- Rotation speed copper (Initial/Final): 55 / 81
- Time hours (Initial/Final): 700 / 1030
- Time to final condition: 4.5
- Balancing speeds (before/after): 450 / 620
- Remarks: Ditto.

Row 4:
- Date of Test: 17.3.21
- Dynamo: Rotex AT.12 593
- Ambient temp (Initial): 15
- Field Teef (Initial/Final): 95 / 130
- Rotation speed copper (Initial/Final): 80 / 115
- Time hours (Initial/Final): 560 / 970
- Time to final condition: 2.1 Not reached
- Balancing speeds (before/after): 345 / 450
- Remarks: Amps. after 2.6 hrs. 8.4 Amps. Temp. too high to cont.
- Handwritten Note: Control brush set to give more output than at maker's position

Row 5:
- Date of Test: 13.4.21
- Dynamo: Smith 2D. (7) RR.2.
- Ambient temp (Initial): 16
- Field Teef (Initial/Final): 80 / 99.5
- Rotation speed copper (Initial/Final): 64 / 83.5
- Time hours (Initial/Final): 645 / 950
- Time to final condition: 4.5
- Balancing speeds (before/after): 475 / 4595
- Remarks: 9 amps. maintained through out test.

Row 6:
- Date of Test: 28.4.21
- Dynamo: U.S.A K Bosch. 41C. 3.065
- Ambient temp (Initial): 14
- Field Teef (Initial/Final): 72 / 98.5
- Rotation speed copper (Initial/Final): 58 / 76.5
- Time hours (Initial/Final): 750 / 1350
- Time to final condition: 3.2
- Balancing speeds (before/after): 450 / 570
- Remarks: 9 amps very nearly maintained till end of test.
- Handwritten Note: Control brush set to give a little more output than at maker's position

Row 7:
- Date of Test: 23.5.21
- Dynamo: Smith 2D (8) R.R.3. 2111
- Ambient temp (Initial/Final): 19 / 24
- Field Teef (Initial/Final): 79 / 107.4
- Rotation speed copper (Initial/Final): 60 / 86.4 66+
- Time hours (Initial/Final): 650 / 1015
- Time to final condition: 4.75
- Balancing speeds (before/after): 440 / 525
- Remarks: 9 amps. maintained.

FOOTNOTE:
+ Corresponding to 12.4 C.C. Volts before and 13.6 C.C. Volts after.
  
  