Letter from Bosch Limited explaining the potential causes of a dynamo failure, specifically melted and welded contacts.

Identifier  ExFiles\Box 60\4\  Scan129
Date  22th December 1931
  
TELEPHONE: SHEPHERD'S BUSH 2080 (4 LINES)
TELEGRAMS: ELECBRIGHT, ACT, LONDON

BOSCH LIMITED
HEAD OFFICES:
LARDEN ROAD, ACTON
LONDON, W.3.

DIRECTORS:
P. J.{Mr Johnson W.M.} A.{Mr Adams} CLAUSEN (British of Danish Origin)
E.{Mr Elliott - Chief Engineer} SCHWER (German)
G.{Mr Griffiths - Chief Accountant / Mr Gnapp} JONES
H.{Arthur M. Hanbury - Head Complaints} P. BAZELEY

GLASGOW:
222, BOTHWELL ST.{Capt. P. R. Strong}, C.2
PHONE: CENTRAL 3154
TELEGRAMS: ELECBRIGHT, GLASGOW

SOLE AGENTS IN GT. BRITAIN & IRELAND FOR
BOSCH PRODUCTS
MADE BY ROBERT BOSCH A.{Mr Adams} G.{Mr Griffiths - Chief Accountant / Mr Gnapp} STUTTGART
MAGNETOS - DYNAMOS - ELECTRIC STARTERS - SPARKING PLUGS - BICYCLE LIGHTING SETS - HORNS - HEADLAMPS - INJECTION PUMPS - NOZZLES - ACCESSORIES - LUBRICATORS

JWH/FW

Messrs. Rolls-Royce Ltd.,
DERBY

Ref: Hs{Lord Ernest Hives - Chair}/Wst.3/AD

December 22nd, 1931.

Dear Sirs,

We are in receipt of your letter of the 17th inst., and thank you for the information contained therein.

The cause of the failure of the dynamo is due to the lower contacts of the regulator being melted away, and the upper contacts becoming welded together. The cause of the lower contacts being melted away could be due to running the dynamo with the field resistance coil open circuited. In these circumstances the lower contacts would be destroyed in a few minutes.

With regard to the welding of the upper contacts this could be caused by a short-circuit between the regulator angle piece and the frame of the dynamo. We would ask you, therefore, if you would be kind enough to make investigations at your end to ascertain whether it is possible that you have run the dynamo with the cable of the field resistance disconnected and that there has also been, not necessarily at the same time, a short circuit between the regulator angle piece and the frame. If you find that this has occurred whilst testing, then we need not look any further for an explanation.

Adverting to your letter of December 15th, ref: Hs{Lord Ernest Hives - Chair}/Wst/s/MA, when you asked -