Heat treatment procedure for aluminium brake drums to prevent shrinkage.
| Identifier | ExFiles\Box 85\1\ scan0092 | |
| Date | 13th May 1936 | |
| NOT SENT OUT x206 To RHG. c. to By. {R.W. Bailey - Chief Engineer} c. to Hl. Aluminium Brake Drums. --- We have had a case of an aluminium drum shrinking after use and tightening on to its hub. As the liners are shrunk in with a known interference to give definite results we think stresses of an unknown quantity set up by such contractions are undesirable. Hl. has prescribed the following treatment for all aluminium drum castings :- (1) Raise casting to 520 - 530°C. and soak at this temperature for 1½ hours. (2) Quench from this temperature in lukewarm water (35°C.). (3) Soak at 170°C. for 24 hours (The Brinel figure should then be 130-140). (4) Soak at 200°C. for 12 hours (The Brinell figure should still be 130-140). Will you please instruct that all aluminium drums receive this treatment. It is especially necessary in the case of E.R. Hall's drums for B-35-AE, even though completion is delayed by this prolonged soaking. Hs {Lord Ernest Hives - Chair} /A.F.Martindale. | ||