Graph comparing heat dissipation performance of Marston Mk V 52mm and 65mm radiator cores against air speed.


Identifier  ExFiles\Box 149a\2\  scan0273
Date  20th August 1935 guessed
  
HEAT DISSIPATED / MIN / °C-DIFF BETWEEN AIR & WATER INLET TEMPS . B.Th.U's.
Top Axis Values: 10, 20, 30, 40, 50, 60
Left Axis Label: AIR SPEED THRO' CORE — FT/SEC
Left Axis Values: 10, 20, 30, 40, 50
Right Text Box: VARIATION OF COOLING WITH AIR SPEED THRO' CORE (ASSUMING FREE AREA = FRONTAL AREA OF MATRIX)
Upper Curve Equation: H = K . V^0.795
Upper Curve Label: MARSTON MK V 65 M {Mr Moon / Mr Moore} /M
Lower Curve Equation: H = K . V^0.79
Lower Curve Label: MARSTON MK V 52 M {Mr Moon / Mr Moore} /M
SHEET 6.
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).