Results of cooling tests conducted at Brooklands on the 37 EX car, comparing different radiator matrix and fan configurations.

Identifier  ExFiles\Box 94\3\  scan0225
Date  24th June 1937 guessed
  
(SHEET 3)
RESULTS OF COOLING TESTS CARRIED OUT
AT BROOKLANDS ( 40 MPH FULL THROTTLE ) ON 37 EX CAR

CONDITIONS OF TEST AIR TEMP DURING TESTS °C CRITICAL AIR TEMP °C
STD. MATRIX B.S.O 16.5 35.0
STD. FAN
STD. MATRIX B.S.O 24.0 38.0
5 BLADE FAN 1.0/1 RATIO
STD. MATRIX B.S.O 24.0 41.5
5 BLADE FAN 1.1/1 RATIO
STD. MATRIX B.S.O 18.0 42.0
5 BLADE FAN 1.2/1 RATIO
LIGHTENED MATRIX B.S.O 21.0 27.0
STD. FAN
LIGHTENED MATRIX B.S.O 21.0 30.0
5 BLADE FAN 1/1 RATIO
HARRISON MATRIX B.S.O 24.0 38.5
5 BLADE FAN 1/1 RATIO
GALLAY MATRIX ( 60 M.M. ) B.S.O 25.5 25.5
5 BLADE FAN 1/1 RATIO
MATRIX WITH AIR SLOTS B.S.O 22.0 28.5
5 BLADE FAN 1/1 RATIO

NOTE
(A) B.S.O DENOTES BONNET SHUTTERS OPEN
(B) CRITICAL AIR TEMP IS MINIMUM ATMOSPHERIC TEMP NECESSARY FOR WATER TO REACH 100°c IF DRIVEN AT 40 MPH FULL THROTTLE LONG ENOUGH.
(C) MINIMUM ATMOSPHERIC TEMP FOR WATER LOSS TO OCCUR IS 5°c ABOVE CRITICAL AIR TEMP (OWING TO STEAM VALVE)
  
  