Air and top water temperature readings for runs using large and small tube radiators.


Identifier  ExFiles\Box 11\3\  03-page439
Date  14th July 1931
  
25-EX. 14.7.31.

Air and top Water temperature taken during
run from Chateauroux(French test region) to the Col-de-la {L. A. Archer} -Faucile.
with Large Tube Radiator.

Air. 25.5 26.0 26.5 26.5 27 28 30.5 30.25 30 29.5 29 29
Water. 81 86 82 83 87 90 91 82 87 86 70 86


From Col-de-la {L. A. Archer} -Faucile to Chateauroux(French test region).
with Small Tube Radiator.

Air. 13 12 16 19 19 20 21 20 22 21.5 22 21.5
Water. 58 62 69 70 72 68 76 73 65 75 72 72.5


Distance 314 miles each way.