Formulas and variable definitions for centrifugal blowers.


Identifier  ExFiles\Box 173\2\  img018
Date  22th March 1933 guessed
  
Centrifugal Blowers.

No. / Tu

ηu = (3.2 * W) / (u * P₁ * A * (1/T₁ + R {Sir Henry Royce} /T₂)) = (3.2 * W * T₁ * ψ) / (u * P₁ * A * (R - 1))

K = (R - 1) / (u² * (1/T₁ + R {Sir Henry Royce} /T₂)) = (T₁ * ψ) / u²

W = Delivery (lbs/min)
u = Tip speed (ft/sec)
P₁ = Inlet pressure (lbs/o'')
A = Rotor peripheral area (sq ins)
T₁ = Inlet temperature (°K)
R = Compression ratio

ψ = (R - 1) / (1 + (R^((γ-1)/γ) - 1) / ηa)

ηa = Adiabatic efficiency
γ = Ratio of sp. {Mr Spinney} heats.
  
  