Test figures for component temperatures during vehicle operation in dense London traffic.

Identifier  ExFiles\Box 155\1\  scan0301
Date  24th August 1937 guessed
  
(SHEET 2)

TEST FIGURES OBTAINED WHEN RUNNING IN LONDON TRAFFIC

(NOTE TESTS WHERE CARRIED OUT BY RUNNING FOR 1 HOUR IN THE MOST DENSE TRAFFIC WHICH COULD BE FOUND)

| CONDITIONS OF TESTS | AIR TEMP DURING TESTS | MAX TOP WATER TEMP REACHED | MAX BOTTOM WATER TEMP | MAX. AIR TEMP BEHIND FAN | MAX. AIR TEMP AT PETROL PUMPS | MAX PUMP FEED TEMP | CRITICAL AIR TEMP FROM IDLING TESTS |
|---|---|---|---|---|---|---|---|
| AS STD B.S.C | 18 | 97 | 92.5 | 85 | 67 | 53 | 9.5 |
| STD MATRIX B.S.O | | | | | | | |
| 5 BLADE FAN 1.1/1 RATIO | 21 | 81 | 73.5 | 70 | 59 | 46 | 30 |
| MATRIX WITH AIR SLOTS B.S.O | | | | | | | |
| 5 BLADE FAN 1.0/1 RATIO | 26 | 88 | 81 | 71 | 60 | 51 | 31.5 |
| HARRISON MATRIX B.S.O | | | | | | | |
| 5 BLADE FAN 1.0/1 RATIO | 29 | 86.5 | 77.5 | 73 | 66 | 57 | 27.0 |

NOTE
B.S.C - INDICATES BONNET SHUTTERS CLOSED
B.S.O - INDICATES BONNET SHUTTERS OPEN
WATER LOSS DOES NOT OCCUR UNTIL TOP WATER TEMP REACHES 105°C ( DUE TO STEAM VALVE).
  
  