Technical specification and breakdown voltage test results for various types of electrical cables.

Identifier  ExFiles\Box 167\3\  img137
Date  19th January 1939
  
(1)
Attached to Rm{William Robotham - Chief Engineer}/RC.{R. Childs}8/JH.19.1.39.

Type of cable.
Breakdown Complete cable.
Voltage rubber only.

(1) R.176/1 - 14/36: Black laquer finish over cotton braid and yellow tape.
Overall diameter .160 inches.
Diameter of rubber .095 inches.
13,050
13,880

(2) R.276/1 - 23/36: Finish as (1)
Overall diameter .153 inches
Diameter of rubber .090 inches.
8,400
5,500

(3) RL.276/1F - 23/36 : Clear varnish finish over cotton braid.
Overall diameter : .127 inches.
Diam. of rubber .090 inches.
10,300
6,000

(4) S.276/1 - 23/36 aluminium laquer over cotton braid.
Overall diameter .145 inches.
Diameter of rubber .090 inches.
9,500
3,000

(5) R2A76/1 - 40/36 Finish as (1).
Overall diameter .164 inches
Diameter of rubber .105 inches.
8,700
3,000

(6) S2A76/1 - 40/36 Finish as (4)
Overall diameter : .153 inches
Diameter of rubber .107 inches.
4,700
3,500

(7) S3A76/1 - 110/36 Finish as (4)
Overall diameter .205 inches.
Diameter of rubber .138 inches.
6,600
3,000

Breakdown between the two cores.

(8) RL.176/2F - 2x14/36 twin cable.
Finish as (3)
Overall dimensions .155 x .205 inches.
17,200 volts.

(9) S172/2 - 2 x 14/36 Finish as (3).
Overall dimensions .168 x .220 inches.
No breakdown at 19,200 volts.
  
  