Explanation of primary and secondary oscillations within a high-frequency air core transformer and magneto ignition systems.
| Identifier | ExFiles\Box 4\5\ 05-page085 | |
| Date | 1st August 1920 | |
| A.M. SECTION No. 11A, Issue 1. AUG 1920 -16- Contd. of the primary oscillation, so that at every instant while these two oscillations last they annihilate one another in their effect on the armature core. In other words, for the time being, the primary and secondary are acting together as a high frequency air core transformer. The energy previous-ly/inductively in the primary winding is thrown on to the secondary and the oscillatory discharge across the secondary gap constitutes the initial bluish-white spark which is characteristic of any high tension discharge of a magneto or induction coil. It has already been pointed out that this initial oscillatory spark is not accompanied by a corresponding oscillation of flux in the armature core. It will be remembered, however, that previous to this instant but after the point of primary break, a portion of the total redistribu-tion of armature core flux has taken place at a rate which must be considered slow as compared with the quick oscillation constituting the initial spark, but nevertheless great as compared with the subsequent redistribution of flux corresponding to the arc discharge, which we will now consider. Superposed upon the quick initial spark oscill-ation of which we have spoken, there has sprung up at the instant when the secondary discharge began, a secondary non-oscillatory discharge current whose initial value is the exact equivalent of the current existing in the primary, just previous to at this instant (reduced in the ratio of the numbers of turns) and which as regards maintaining the flux which yet exists in the Contd. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).