Performance graph for a Bentley Radiator (Marston Mark V).


Identifier  ExFiles\Box 149a\2\  scan0364
Date  28th February 1936
  
L 610 B1
BENTLEY RADIATOR (MARSTON MARK V)
FRONTAL AREA = 3.24 sq ft
FRONTAL ASPECT = 23 7/8" HIGH x 19 5/8" WIDE = 3.26 sq ft
COOLING SURFACE =
Nº OF WATER PASSAGES = 32
DEPTH OF BLOCK = 58 MM.
CONSTANT WATER FLOWS (A) 35 GALLS/MIN (B) 20 GALLS/MIN
AIR INLET 60°F
WATER MEAN 160°F

H.P. DISSIPATED
AIR PRESSURE AT WATER TEMP OF 160°F

Vertical Axis (Left): STATIC DIFFCE IN AIR PRESS. INS. WATER. MATRIX TRUNKED FORE AND AFT.
Vertical Axis (Right): H.P. DISSIPATED / 100°F TEMP. DIFFCE AIR IN TO WATER MEAN.
Horizontal Axis (Top): AIR FACE VELOCITY, MILES PER HR
Horizontal Axis (Bottom): AIR FLOW CU.FT/MIN CALCULATED AT 60°F AND 29.9" Hg

LINCOLN
EJS 28/2/36
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).