Performance curves and the lower efficiency of a sequence starter motor compared to a 6' motor.


Identifier  WestWitteringFiles\P\October1926-November1926\  Scan130
Date  19th November 1926
  
To AJS. from EFC. {E. Fowler Clarke - Electrical Engineer} ORIGINAL EFCa/T19.11.26.

SEQUENCE STARTER MOTOR. K7670

As requested, we now send to you curves shewing the amperes for each torque and the efficiency for each torque, for the sequence starter motor, these curves being an average of three motors upon which we have made brake efficiency tests. You will notice that the efficiency is rather lower than we used to obtain on the 6" motor (present standard).

We regret we are not yet ready with the further information you require. We are attempting, at the same time as recommending new windings, to find out the reason of the lower efficiency of the present sequence starter motor as compared with the 6" motor.

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).