Rolls-Royce Archives
         « Prev  Box Series  Next »        

Test data tables on the cooling efficiency of a 40/50 HP engine, examining the effects of speed, matrix/shutter configuration, and fuel mixture strength.


Identifier  ExFiles\Box 22\1\  Scan221
Date  17th February 1925 guessed
  
INCREASE IN EFFICIENCY OF 40/50 HP. COOLING SYSTEM WITH SPEED. SHEET 4.

20¾" matrix. Road speed. | δt | % difference from 'A'. | Critical atmospheric temperature.
20 M.P.H. - all closed. | 82.2ºC | 'A' | 11.8ºC
30 M.P.H. - " " | 77ºC | 7.5% better. | 18ºC
40 M.P.H. - " " | 71.6ºC | 14% better | 23.4ºC

40/50 HP. WITH 22¾" MATRIX AND LARGE SHUTTERS OPEN COMPARED WITH STD. HISPANO CONDITION 30 MPH.

Car and Ventilation details. | δt | % difference from 'A' | Critical atmospheric temperature.
40/50 HP. 22¾" Matrix. 4 large shutters. Total area 112 sq.in. | 62ºC | 'A' | 33ºC
Hispano - louvres. | 60.7ºC | 2.1% better. | 34.3ºC

AFFECT OF MIXTURE STRENGTH - HISPANO - 30 M.P.H.

Std. rad. conditions. Mixture control. | δt | % difference from 'A'. | Critical ats: temperature.
Strong mixture. | 58ºC | 'A' | 37ºC
Weak mixture. | 63.4ºC | 9.3% worse. | 31.6ºC

Hs {Lord Ernest Hives - Chair} /Rm. {William Robotham - Chief Engineer}
  
  