Cooling performance of a 20 HP car, with reference to attached test results.
| Identifier | ExFiles\Box 77\4\ scan0328 | |
| Date | 27th July 1923 | |
| To P.N. from Hs. {Lord Ernest Hives - Chair} c. to EP. {G. Eric Platford - Chief Quality Engineer} c. to BY. {R.W. Bailey - Chief Engineer} X4240 Hs {Lord Ernest Hives - Chair} 4/LG27.7.23. RE. 20 HP. COOLING. We certainly should not expect a 20 HP. car to boil in 2 miles running under full power unless there was something obviously wrong. We attach a report and chart giving results of tests with regard to Cooling. It will be seen from this that a car was run full power at 20 M.P.H. for 19 minutes on a fairly hot day without boiling. Hs. {Lord Ernest Hives - Chair} | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).