Performance data table comparing a '4 Cam Pump' and a 'Standard Pump' for a Governor Control Shock Damper.


Identifier  ExFiles\Box 151\2\  scan0067
Date  12th April 1933
  
FILES
X2-35
12.4.33.
GOVERNOR CONTROL - SHOCK DAMPER.

Hs {Lord Ernest Hives - Chair} /Les. Square Cam Operated Pump.
Compressor Oil - Governor as supplied.
Governor Release Pipe Disconnected.

| | 4 Cam Pump. | | Std. Pump. | |
|---|---|---|---|---|
| Road Speed M.P.H. | Pump Press. lb/sq.in. | Delivery Pts/Hr. | Pump Press. lb/sq.in. | Delivery Pts/Hr. |
| 30 | 1 | 50.8 | 1 | 22.4 |
| 60 | 4½ | 83.8 | 3½ | 32.4 |
| 80 | 5½ | 92.4 | 5 | 45 |
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble