Carburetter flooding on the Phantom III, identifying the difference in filter mesh size compared to the 25/30 HP model.
| Identifier | ExFiles\Box 131\4\ scan0241 | |
| Date | 27th May 1937 | |
| Rm. {William Robotham - Chief Engineer} c. Sg. {Arthur F. Sidgreaves - MD} c. Hs. {Lord Ernest Hives - Chair} c. E. {Mr Elliott - Chief Engineer} 1113. BY {R.W. Bailey - Chief Engineer} /Cgh. {W Clough} 7/W.27.5.37. Phantom III - Carburetter Flooding. With reference to Rm. {William Robotham - Chief Engineer} 1/P.25.5.37, the real difference between the filters on Phantom III and 25/30 H.P. is not a dimensional difference so far as size is concerned, but is a difference in the mesh of the filters. The scheme for Phantom III specified 60 mesh filters whereas in the case of the 25/30 H.P., the filter was specified to be made from a sample made by The Stromberg Company, which was found to be 100 mesh. BY {R.W. Bailey - Chief Engineer} /Cgh. {W Clough} | ||