Low and high rate discharge tests performed on a battery.


Identifier  ExFiles\Box 54\1\  Scan153
Date  2nd November 1925
  
RR 238 (150 BKS.) (DD 431-B 12 24) MP 306975
ROLLS-ROYCE LTD.
INSTRUCTIONS.
To: G.S.h.
Date: 2-11-1925
Order No. JC 140
Customer's No. X 4617P
Re Tests on PcRRR11-3 Battery (182)
This battery is now 2 years old & has run 3166 miles.
On Low Rate Discharge through a constant external resistance of 1.80 w a capacity of 88.9 ampere hours were realised. All cells showed positive weakness.
On High Rate Discharge through a constant external resistance of .100 w
Initial amperes = 110.7
Time to 104 " = 18.6 min
" 103 " = 20.0 "
All cells showed negative weakness.
The above results are an improvement on previous tests taken & no doubt this battery is now at the prime of its life.
Signed: G.J.
This Sheet must be filed on completion of the work.
  
  