Formulae and calculations for determining bonnet temperature using Bypass Control and Shutter Methods.

Identifier  ExFiles\Box 29\3\  Scan352
Date  21th September 1934
  
-2-

Hs{Lord Ernest Hives - Chair}/Std.7/KW.21.9.34.

Let B1 = temp. of air after passing through matrix, with atmospheric temp. of T1

B2 = temp. of air after passing through matrix with atmospheric temp. of T2

M = mean water temp. in radiator, with shutters in operation

All temps. in °C. absolute.

Formulae for determination of bonnet temp. B2

(a) Bypass Control.
B2 = B1 + T2 - T1 - (B1 - T1)(1 - T2/T1)

(b) Shutter Method.
B2 = T2 + (M - T2)/(M - T1) (B1 - T1)

Taking figures obtained at Brooklands (30 M.P.H.), with an air temp. of 20°C, bonnet temps. were respectively (a) 32.0°C. (b) 39.0°C. Mean water temp. = 70°C.

With an air temp. of 0°C, these become
(a) 10.9°C.
(b) 26.6°C.